What the station does
Each rack is checked at the landing, crosses the bridge and is locked by four pins.
A 2.4 t rack passes from a steel tower into a ship standing free on the pad. The landing check decides if it may enter: mass within ± 1 %, tag equal to the plan. In the bay, four pins lock it and sensors confirm the lock.
Step by step
- The landing conveyor takes the rack and stops it on the scale.
- The PLC checks the mass against the rack record within ± 1 %.
- The radio tag reader checks the rack identity against the load plan.
- With the bridge locked and the door open, the conveyor pushes the rack in.
- The ship's lift takes the rack and sets it into its slot.
- Four pins enter the rack feet, and sensors confirm the lock within 5 s.
Specifications
The devices
Each device is a real catalogue product. Its own product page will follow on the products level.
| Device | Role |
|---|---|
| Chain conveyor with 1.5 kW drive | Pushes the rack over the bridge. |
| Load cells, 4 x 1 t | Weigh the conveyor and rack together. |
| Radio tag reader and rack tag | Confirms the rack identity. |
| Light beam sensors (3) | See the rack on landing, bridge and door. |
| Bridge interlock switch | Blocks raising the bridge during the push. |
| Air cylinders with valves (4) | Drive the lock pins into the rack feet. |
Links lead to the makers' public product pages and are given for reference only. This site is independent work, not affiliated with, sponsored or endorsed by any manufacturer. The makers are responsible for the content of their pages. Trademarks belong to their owners.
The signals
| Signal | Direction | Meaning |
|---|---|---|
| Rack mass | to PLC | Weight from four load cells for the check. |
| Rack tag | to PLC | Identity, payload and centre of gravity. |
| Bridge lowered and locked | to PLC | The push is allowed only with this signal. |
| Bay door open | to PLC | Ship signal: the side door is open. |
| Level ready | to PLC | Rack in its slot, pins may lock. |
| Pin locked and unlocked | to PLC | Four locked and none unlocked: lock confirmed. |
About this page
In the scenario, this bridge is the last stretch a rack crosses on 16 Psyche before the flight to the Earth.
Real devices, built from real data
Every machine and device in this twin is a real industrial product from the makers' catalogues. They range from sensors, valves and drives to safety scanners, load cells and RFID readers. Each model is built from the product's published data: dimensions, sensing ranges, signals, rated values, parameters and timing.