Safety
Every area and vehicle has its own safety controller. Emergency stops, light curtains and scanners cut motor power through safe torque off. Safety never runs over the radio. Design targets, not claims: performance level d and safety integrity level 2. The twin's safety logic is a test model only, not a validated safety function.

The safety functions
Emergency stop
Two-channel buttons and pull-rope switches stop drives at once. Restart needs acknowledgement. Standards applied: ISO 13850 for the emergency stop; IEC 60204-1 for the stop categories 0 and 1; ISO 13849-1 with performance level d as the target, not a claim.
Guard doors with locking
Doors unlock only after the hazard stops. An open door always stops the machine. Standards applied: ISO 14119 for the interlocks and the guard locking; ISO 14120 for the fixed guards; ISO 13857 for the reach distances at the guards.
Light curtains and muting
Light curtains of the highest type guard openings. Muting lets loads pass, not people. Standards applied: ISO 13855 for the safety distances; IEC 62046 for muting; IEC 61496 for the light curtains; performance level d as the target.
Laser scanners on vehicles
Fields change with speed. A person in them slows, then stops the vehicle. Standards applied: ISO 3691-4 for the fields and speeds of the driverless vehicles; scanners rated performance level d, category 3, by their data sheet.
Hard-wired dock interlocks
Cart presence, pin and rack edges are wired to the station, never over radio. Standards applied: ISO 13849-1 with performance level d as the target for the dock functions.
Hot metal interlocks
Dry charge only. A tap needs the ladle car pinned and the pit clear. Standards applied: IEC 60204-1 stop category 0 for the furnace power and the hydraulics; ISO 13849-1 with performance level d as the target.